Description
FC36M | 230V 3-Phase Dual Mode Thyristor Driver (c/w DIN Housing)
The FC36M 230V Dual Mode Firing Board with DIN Housing is a microprocessor-based three-phase thyristor driver designed for reliable SCR (thyristor) control in industrial power control systems. Housed in a robust DIN rail enclosure, it provides easy installation within electrical control panels while delivering accurate phase-angle and burst-fire firing for resistive and inductive loads.
Designed for seamless integration into power control assemblies, the FC36M eliminates the need for external phasing supply transformers by requiring only simple gate/cathode outputs. Available in 110V, 230V, 415V and 480V supply versions, this model is configured for 230V AC operation and includes opto-isolated control inputs, adjustable ramp control, over-current protection, LED status indicators and an RJ45 communications port.
Key Features
The FC36M 230V Dual Mode Thyristor Driver with DIN Housing provides flexible SCR firing control with comprehensive protection and convenient DIN rail mounting for industrial control panels.
- 230V AC supply version
- Supplied complete with DIN rail enclosure
- Microprocessor-based three-phase thyristor driver
- Dual operating modes: Phase Angle and Burst Fire
- Switch-selectable phase reversal
- Suitable for resistive and inductive loads
- Analogue and digital opto-isolated control inputs
- Adjustable soft-start ramp (0–30 seconds)
- Current limit and over-current latching protection
- LED status indicators for system monitoring
- RJ45 communications port for integration
- Simplified wiring with no external phasing transformer required
Technical Specifications
- Supply Voltage: 230V AC ±10%
- Frequency: 50/60Hz
- Controller Type: Microprocessor-based three-phase thyristor driver
- Operating Modes: Phase Angle or Burst Fire (switch selectable)
- Primary Fusing: Two HRC F1A ceramic fuses (20 × 5mm)
- Current Consumption: 350mA (full conduction)
- Initial Short-Circuit Gate Current: 500mA
- Sustaining Short-Circuit Gate Current: 250mA
- Initial Pulse Voltage: 9V
- Sustaining Pulse Voltage: 5V
- Pulse Train Frequency: 25kHz
- Voltage Control Inputs: 0–5V DC or 0–10V DC
- Input Resistance: 10kΩ / 20kΩ
- Current Control Input: 4–20mA
- Current Input Resistance: 240Ω
- Opto-Isolated Digital Inputs: 5–24V DC
- Ramp Adjustment: 0–30 seconds
- Current Limit / Over-Current Trip: 0–100mV DC or 0–25V DC
- Load Selection: Resistive or Inductive (SW4 selectable)
- Operating Temperature: 0°C to +65°C
- Storage Temperature: 0°C to +65°C
- DIN Enclosure Dimensions: 166mm (L) × 128mm (W) × 70mm (H)
Operation
The FC36M generates precise gate firing pulses for three-phase SCR power controllers. Users can select between phase-angle control for smooth proportional power regulation or burst-fire control for efficient switching of resistive heating loads.
The controller accepts analogue voltage, current or digital opto-isolated input signals. Adjustable ramp control provides controlled power-up, while integrated over-current protection and configurable load selection help ensure safe, reliable operation across a wide range of industrial applications.
The supplied DIN rail housing simplifies installation into electrical control cabinets while protecting the firing electronics.
Applications
The FC36M 230V Dual Mode Thyristor Driver with DIN Housing is ideal for:
- Three-phase SCR power controllers
- Industrial power supplies
- Half-controlled rectifiers
- Fully controlled rectifiers
- AC motor control
- DC motor control
- Soft starter systems
- Electric heater controllers
- Induction generators
- AC voltage regulators
- Industrial process control
- Manufacturing equipment
- Control panels and switchgear
- Power conversion systems
Benefits
- Supplied ready for DIN rail mounting
- Precise three-phase SCR firing control
- Supports both phase-angle and burst-fire operation
- Simplifies wiring and installation
- Compatible with analogue and digital control signals
- Adjustable soft-start reduces electrical stress
- Built-in over-current protection improves system reliability
- Suitable for both resistive and inductive loads
- Reliable microprocessor-based operation
- Easy integration into industrial automation systems
Safety & Installation
- Installation should only be carried out by suitably qualified personnel.
- Isolate all power supplies before installation or maintenance.
- Ensure the correct 230V AC supply is used.
- Mount the enclosure securely onto a compatible DIN rail.
- Fit appropriate external circuit protection in accordance with local electrical regulations.
- Configure the operating mode and load type before commissioning.
- Ensure adequate ventilation is provided within the control enclosure.