Description
The PR3-DIN range of thyristor stacks offers seamless control of three-phase electric heating loads from a Building Management System (BMS) or similar controller. Utilizing zero volts switching technology, these burst firing controllers minimize Radio Frequency Interference (RFI) issues. Available in 12kW and 18kW models for a typical AC voltage supply of 415V, they employ a two-thirds control technique. Key features include DIN rail mounting capability, DC voltage signal control, temperature trip with automatic reset, alarm output, and LED ‘OUTPUT-ON’ indication. Additionally, these models provide easy access to internal signal and power terminals and require no additional heatsink for any power rating.
Applications
The PR3-E Series is ideal for controlling electric heating coils, heating cables, and electric furnaces. Its robust design ensures reliable performance in various industrial heating applications.
Key Features
- Seamless Three-Phase Control: Efficiently manages three-phase electric heating loads.
- Zero Voltage Switching: Minimizes RFI issues for a smoother operation.
- Two-Thirds Control Technique: Available in 12kW and 18kW models for 415V AC supply.
- DIN Rail Mounting: Easy installation on TS35 section DIN rail.
- Temperature Trip with Automatic Reset: Ensures safety with over-temperature protection.
- Alarm Output: Provides 24V AC or DC alarm output, indicating over-temperature or power supply failure.
- LED Indicators: Displays ‘OUTPUT-ON’ status for easy monitoring.
- No Additional Heatsink Required: Simplifies installation and reduces additional component costs.
Technical Specifications
- Power / Current Ratings: 12kW (17A), 18kW (25A) @ 415V RMS
- Input Voltage: 3-phase from 24V to 440V AC RMS
- Frequency: 50/60Hz
- Input Signal: 0 to 10V DC
- Power Supply: Remote 24V AC or DC ± 10% @ 40mA (not supplied)
- Terminal Ratings: Rising clamp terminal block for 2.5mm² cable entry (Input signal/alarm/24V supply input)
- Alarm Output: 24V AC or DC (as power supply) drops to 0V in the event of over-temperature or power supply failure
- Over-Temperature Protection: Trip in temperature at 90°C ± 5°C, trip out temperature at 85°C ± 5°C
- Status Indicator: T1 and T3 indicate output ratio
- Power Terminations: Rising clamp terminal block for 6mm² cable entry
- Terminal Torque Settings: 0.8Nm (Power Terminals Only)
- Fusing: 12kW: 20A (20ET), 18kW: 30A (32ET) – High-Speed Semiconductor type fuses or equivalent MCBs
- Max. Ambient Temperature: 40°C
- Dimensions:
- 12kW: 217mm (W) x 87mm (H) x 90mm (D) (including DIN clips) – firing circuit terminals front facing
- 18kW: 217mm (W) x 87mm (H) x 110mm (D) (including DIN clips) – firing circuit terminals front facing
- Weight:
- 12kW: 0.6kg
- 18kW: 0.95kg
The PR3-E Series provides a reliable and efficient solution for controlling three-phase electric heating loads, offering easy installation and robust performance tailored for industrial HVAC applications.