Description
PAC2 Phase Angle Firing Module (25A 6kW AC Control)
The PAC2 from United Automation is a compact, high-power, full-wave AC phase-angle controller designed for precise power regulation in demanding industrial and commercial equipment. Capable of controlling up to 6kW (25A) at 230V, the PAC2 modulates the AC phase angle to deliver accurate, proportional power to the load.
Built using surface-mount technology with low thermal impedance and high electrical isolation, the PAC2 offers excellent reliability and flexibility for equipment designers. An internal snubber network helps eliminate nuisance switching, ensuring stable operation with inductive and resistive loads.
Key Features
- Solid-state reliability for long service life
- Surface-mount design for compact integration
- Wide AC supply range: 50–250V AC
- Rugged, compact construction
- Up to 25A capability with additional heatsinking
- Internal snubber network to prevent nuisance triggering
- High isolation for safe and stable operation
Technical Specifications
- AC line voltage range: 50–250V AC @ 50/60Hz
- Unit limiting RMS current: 25A
- Peak one-cycle surge (10ms): 250A
- Minimum operating current: 50mA
- Isolation voltage: 3.5kV RMS
- Recommended potentiometer: 5kΩ
- Storage temperature: 0°C to 65°C
- AC auxiliary input supply: 10V AC ±2V @ 50mA
- I²t for fusing: 250 A²s
- Maximum peak voltage: 600V
- Leakage current: 5mA
- Control signal: 0–5V DC or 5V auxiliary output (for potentiometer)
- Power consumption: 1.2W
- Maximum operating temperature: 65°C
- Weight: 63g
Dimensions & Fixing
- Size: 57mm (D) × 44mm (W) × 28mm (H)
- Fixing centres: 48mm pitch, 2 × 4.5mm Ø holes (M4 clearance)
Connections
- AC auxiliary input supply terminals: M3 × 10mm screws (spade/eyelet)
- AC line voltage terminals: M5 × 10mm screws (spade/eyelet)
Applications
Ideal for accurate phase-angle power control in:
- Ovens and dryers
- Commercial kitchens and catering equipment
- Quartz and infrared heat lamps
- Moulding and process heating equipment
- Inductive loads such as transformers and motors
A Transformer (T30201) is required to provide power and timing for the unit.
| TECHNICAL SPECIFICATIONS | ||
|---|---|---|
| AC Line Voltage Range | 50 – 250V @ 50/60Hz | |
| Unit Limiting RMS Current | 25A | |
| Peak One-cycle Surge (10ms) | 250A | |
| Minimum Operating Current | 50mA | |
| Isolation Voltage | 3.5kV RMS | |
| Recommended Potentiometer | 5kΩ | |
| Storage Temperature | 0 – 65°C | |
| AC Aux Input Supply | 10V AC ±2V @ 50mA | |
| I2t for Fusing | 250A2 s | |
| Max. Peak Voltage | 600V AC | |
| Leakage Current | 5mA | |
| Control Signal (3-way 0.1” header) | 0-5V or 5V Aux O/P (for pot.) | |
| Power Consumption | 1.2W | |
| Max. Operating Temperature | 65°C | |
| Weight | 63g | |
| Further Dimensions | ||
| Dimensions | 57mm (D) x 44mm (W) x 28mm(H) | |
| Fixing Centre’s | 48mm pitch with 2@ 4.5mm Ø (M4 clearance) holes | |
| Connections | AC AUX Input Supply Terminals | (2x) M3 x 10mm pozi set screws (for use with spade or eyelet crimp connectors) |
| AC Line Voltage Terminals | (2x) M5 x 10mm pozi set screws (for use with spade or eyelet crimp connectors) | |